Implantable Pressure Sensor Encapsulation for Ventricular Assist Device Control

Matthias Alexander Dupuch

Taal: Engels

Uitgever:

Hartung & Gorre

EngelsPaperback978386628834820 december 2024194 pagina's

Samenvatting

Autonomous feedback controlled ventricular assists device (VAD) operation promises a plethora of benefits such as increased patient safety, comfort, and reduced healthcare costs. Current generation VADs operate at static pump speeds due to the lack of available biocompatible, long-term stable pressure sensor systems.In this thesis, a pressure sensor encapsulation was developed and integrated in an inflow cannula for a VAD and in an implantable testing platform for animal trials. The encapsulation uses a media separating diaphragm embedded in a Parylene C coating. The approach is expanded to enable optimized diaphragm shapes, which allow significantly better control over the final device characteristics, especially the temperature cross sensitivity.Furthermore, a production processes was developed to minimize assembly induced internal overpressure.The produced capsules showed excellent pressure transmission of more than 99.7 % and a temperature cross sensitivity of less than 266 Pa from 35 °C to 42 °C for most capsules. However, a large temperature cross sensitivity was observed from room to body temperature in some capsules, adding relevant drift of 750 Pa (75 % quartile) after 42 days to the measurement.The observed drift is related to the viscoelastic nature of the Parylene C diaphragm and the capsule-to-capsule variation is attributed to production process variations, which can be further optimized.Systematic errors in the pressure transmission, temperature cross sensitivity (TCS), and drift were extracted and correction approaches for each were developed. This enabled the reduction of the pressure transmission error by 50 % by linear correction. A differential measurement approach reduced the temperature cross sensitivity to less than 70 Pa from 35 °C to 42 °C and drastically reduced the temperature induced drift to 300 Pa (75 % quartile) after a jump from room to body temperature. Half of all sensors even remained within a +- 100 Pa window in the same time period.

Productspecificaties

Inhoud

Taal
en
Uitvoering
Paperback
Oorspronkelijke releasedatum
20 december 2024
Aantal pagina's
194

Betrokkenen

Tweede Auteur
Hoofdredacteur
Hoofduitgeverij

Informatie over de fabrikant

Fabrikant Naam
info@bod.de
Elektronisch adres fabrikant
info@bod.de
Fabrikantgegevens
De overige informatie van de fabrikant is momenteel niet beschikbaar.

Overige kenmerken

Product breedte
170 mm
Product hoogte
10 mm
Product lengte
244 mm
Verpakking breedte
170 mm
Verpakking hoogte
10 mm
Verpakking lengte
244 mm
Verpakkingsgewicht
318 g

EAN

EAN
9783866288348

Productveiligheid

Verantwoordelijk marktdeelnemer in de EU

Je vindt dit artikel in

Boek, ebook of luisterboek?
Beschikbaarheid
Taal
Type boek

Reviews

Nog geen reviews

Kies gewenste uitvoering

Kies je uitvoering
Prijsinformatie en bestellenDe prijs van dit product is 34 euro en 99 cent.
Verwacht over 3 weken
Verkoop door bol
  • Gratis verzending door bol vanaf 25 euro

  • Ophalen bij een bol afhaalpunt mogelijk

  • 30 dagen bedenktijd en gratis retourneren

  • Wettelijke garantie via bol

  • Dag en nacht klantenservice

Bekijk retourvoorwaarden

Bekijk ook eens

Nooduitgang

Zelfzorg voor de jonge dokter

Omgaan met verandering in de zorgsector

Doe ik het wel goed als zorgverlener?

Word je van groeien groter?