Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography Ebook Tooltip

Afbeeldingen

Inkijkexemplaar

Artikel vergelijken

  • Engels
  • E-book
  • 9783656894186
  • 10 februari 2015
  • 82 pagina's
  • Adobe ePub
Alle productspecificaties
  • Je leest ebooks gemakkelijk op je Kobo e-reader, of op je smartphone of tablet met de bol.com Kobo app. Let op! Ebooks kunnen niet geannuleerd of geretourneerd worden.

Samenvatting

Research Paper (postgraduate) from the year 2014 in the subject Medicine - Radiology, Nuclear Medicine, grade: A, , language: English, abstract: This study was the first of its kind in that it fills the gap in the scientific data created by the absence of any investigation making a direct comparison between 2D-sonograhpic and true urine volumes. While most hospitals in the developed world now prefer to measure urine volumes with portable bladder scanners and 3D ultrasound devices, none of these technology are widely available in Bangladesh and other developing countries. Nonetheless, hundreds to thousands of ultrasound examinations involving the measurement of maximum cystometric capacity (MCC) and postvoid residue (PVR) of urinary bladder are done with 2D stationary ultrasound every day. Despite our clinical experience that these measurements are quite accurate and reliable, it was deemed essential to establish scientific evidence in its favour. This observational study was done in the Dept of Radiology & Imaging at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh, during the period July - December 2014. 384 adult patients who came to BSMMU for ultrasound examinations were enrolled in this study and their true urine volumes were compared against that calculated using 2D B-mode ultrasound. The findings were analysed using two statistical approaches - correlation coefficient and limits of agreement. Calculation of the correlation coefficient was done so that the findings of this study could be compared with other relevant studies, most of which have used the correlation coefficient to assess the accuracy of the ultrasound equipment (3D or portable). However, Bland & Altman's limits of agreement method is the standard statistical approach to assess agreement between two methods of clinical measurement, as determined by The Statistician, The Lancet and others. Findings of this study show that bladder urine volumes measured by 2D B-mode ultrasound had high correlation (r = 0.96, 95% CI 0.955 - 0.969, P <0.0001) and agreement (96.35%, LoA : -7.84 ± 53.05 mL) with true urine volumes. Sonographic urine volumes were accurate in both males and females, of all adult age groups and at all volume ranges including <100 mL.

Productspecificaties

Inhoud

Taal
en
Bindwijze
E-book
Oorspronkelijke releasedatum
10 februari 2015
Aantal pagina's
82
Ebook Formaat
Adobe ePub
Illustraties
Nee

Betrokkenen

Hoofdauteur
Muhammad Shoyab
Hoofduitgeverij
Grin Verlag

Lees mogelijkheden

Lees dit ebook op
Android (smartphone en tablet) | Kobo e-reader | Desktop (Mac en Windows) | iOS (smartphone en tablet) | Windows (smartphone en tablet)

Overige kenmerken

Editie
1
Studieboek
Ja

EAN

EAN
9783656894186

Je vindt dit artikel in

Taal
Engels
Studieboek of algemeen
Algemene boeken
Beschikbaarheid
Leverbaar
Boek, ebook of luisterboek?
Ebook
Nog geen reviews

Kies gewenste uitvoering

Bindwijze : E-book

Prijsinformatie en bestellen

De prijs van dit product is 18 euro en 99 cent.
Direct beschikbaar
Verkoop door bol
  • E-book is direct beschikbaar na aankoop
  • E-books lezen is voordelig
  • Dag en nacht klantenservice
  • Veilig betalen
Houd er rekening mee dat je downloadartikelen niet kunt annuleren of retourneren. Bij nog niet verschenen producten kun je tot de verschijningsdatum annuleren.
Zie ook de retourvoorwaarden